Sign In | Join Free | My himfr.com
Home > Infectious Disease Test Kit >

Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit

CITEST DIAGNOSTICS INC.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit from wholesalers
     
    Buy cheap Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit from wholesalers
    • Buy cheap Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit from wholesalers
    • Buy cheap Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit from wholesalers

    Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit

    Ask Lasest Price
    Brand Name : Citest
    Model Number : IMPM-402/IMP-425
    Certification : CE
    Price : negotiation
    Supply Ability : 10 M tests/month
    Delivery Time : 2-4 Weeks
    • Product Details
    • Company Profile

    Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit

    Product featuresParameters
    PrincipleChromatographic Immunoassay
    FormatCassette
    SpecimenWB/S/P
    CertificateCE
    Reading Time10 minutes
    Pack25 T/40 T
    Storage Temperature2-30°C
    Shelf Life2 Years

    Mycoplasma Pneumoniae IgG/IgM Rapid Test, whole blood, serum, or plasma,Infectious Disease Test Kit


    A rapid test for the qualitative detection of IgG and IgM antibodies to Mycoplasma Pneumonia (M. pneumonia) in whole blood, serum or plasma CE certified


    Applications:


    The Mycoplasma Pneumonia IgG/IgM Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of IgG and IgM antibodies to Mycoplasma Pneumonia in whole blood, serum, or plasma to aid in the diagnosis of Mycoplasma Pneumonia infection.


    Description:


    Mycoplasma pneumonia is the causative agent of respiratory tract nfectious diseases and complication of other systems. There will be a symptom with headache, fever, dry cough, and muscle pain. People of all age groups can be infected while youth, middle-aged and children under 4 years old have a higher infection rate. 30% of the infected population may have a whole lung infection.


    In normal infection, MP-IgG can be detected as early as 1 week after infected, continue to rise very rapidly, peaking in about 2-4 weeks, decreasing gradually in 6 weeks, disappear in 2-3 months. Detection of MP-IgM/IgG antibody can diagnose MP infection in early stage.


    How to use?


    Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.

    Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.


    Place the cassette on a clean and level surface. Hold the dropper vertically, draw the specimen (whole blood/serum/plasma) up to the Fill Line as shown in illustration below (approximately 10μl). Transfer the specimen to the specimen position (S) each, then add 2 drops of buffer (approximately 80 μl) to the buffer position (B) each, and start the timer. See the illustration below.

    Wait for the colored line(s) to appear. The result should be read at 10 minutes. Do not interpret results after 20 minutes.


    INTERPRETATION OF RESULTS


    (Please refer to the illustration above)


    POSITIVE:* Two distinct colored lines appear. One colored line should be in the control region (C) and another colored line should be in the test region (T).


    *NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of Mycoplasma Penumonia antibody present in the specimen. Therefore, any shade of color in the test region (T) should be considered positive.


    NEGATIVE: One colored line appears in the control region (C). No apparent colored line appears in the test region (T).


    INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test cassette. If the problem persists, discontinue using the test kit immediately and contact your local distributor.


    Cat. No.Product DescriptionSpecimenFormatKit SizeCut-OffStatus
    IMP-425Mycoplasma Pneumoniae IgG/IgM Combo Rapid Test CassetteWB/S/PCassette25TSee InsertCE
    SUMMARY
    Mycoplasma pneumoniae is the causative agent of respiratory tract nfectious diseases and complication of other systems. There will be a symptom with headache, fever, dry cough, and muscle pain. People of all age groups can be infected while youth, middle-aged and children under 4 years old have a higher infection rate. 30% of the infected population may have a whole lung infection.
    In normal infection, MP-IgG can be detected as early as 1 week after infected, continue to rise very rapidly, peaking in about 2-4 weeks, decreasing gradually in 6 weeks, disappear in 2-3 months. Detection of MP-IgM/IgG antibody can diagnose MP infection in early stage.

    Quality Mycoplasma Pneumoniae IgG IgM Whole Blood Serum Plasma Infectious Disease Test Kit for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: CITEST DIAGNOSTICS INC.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)