Sign In | Join Free | My himfr.com
Home > Infectious Disease Test Kit >

10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection

CITEST DIAGNOSTICS INC.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection from wholesalers
     
    Buy cheap 10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection from wholesalers
    • Buy cheap 10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection from wholesalers
    • Buy cheap 10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection from wholesalers
    • Buy cheap 10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection from wholesalers
    • Buy cheap 10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection from wholesalers

    10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection

    Ask Lasest Price
    Brand Name : Citest
    Model Number : IHI-302/IHI-401/IHI-402
    Certification : qualified
    Price : negotiation
    Supply Ability : 10 M tests/month
    Delivery Time : 2-4 Weeks
    • Product Details
    • Company Profile

    10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection

    Product featuresParameters
    PrincipleChromatographic Immunoassay
    FormatDipstick, Cassette
    SpecimenWB/S/P
    Reading Time10 minutes
    Pack1T/25 T/40T/50T
    Storage Temperature2-30°C
    Shelf Life2 Years

    HIV 1.2 Rapid Test Cassette/Dipstick,diagnosis of HIV infection, fast results in 10 minutes
    Applications:
    Used for the qualitative presumptive detection of antibodies to HIV in human whole blood, serum, or plasma specimens. This kit is intended to be used as an aid in the diagnosis of HIV infection in Hospital, Clinical lab, physician office and other professional organizations

    Features

    Fast results

    Easy visually interpretation

    Simple operation, no equipment required

    High accuracy


    Description:

    HIV is the etiologic agent of Acquired Immune Deficiency Syndrome (AIDS). The virion is surrounded by a lipid envelope that is derived from host cell membrane. Several viral glycoproteins are on the envelope. Each virus contains two copies of positive-sense genomic RNAs. HIV 1 has been isolated from patients with AIDS and AIDS-related complex, and from healthy people with high potential risk for developing AIDS.
    HIV 2 has been isolated from West African AIDS patients and from seropositive asymptomatic individuals. Both HIV 1 and HIV 2 elicit immune response.3 Detection of HIV antibodies in serum, plasma is the most efficient and common way to determine whether an individual has been exposed to HIV and to screen blood and blood products for HIV. Despite the differences in their biological characteristics, serological activities and genome sequences, HIV 1 and HIV 2 show strong antigenic cross-reactivity. Most HIV 2 positive sera can be identified by using HIV 1 based serological tests.
    The HIV 1.2 Rapid Test Cassette (Serum/Plasma) is a rapid test to qualitatively detect the presence of antibody to HIV 1 and/or HIV 2 in serum or plasma specimen. The test utilizes latex conjugate and multiple recombinant HIV proteins to selectively detect antibodies to the HIV 1.2 in serum or plasma.

    How to use?

    IHI-301

    Allow the test, specimen, buffer and/or controls to reach room temperature

    (15-30°C) prior to testing.
    1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it as soon as possible.
    2. Place the cassette on a clean and level surface.
    For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25μL) to the specimen area, then add 1 drop of buffer (approximately 40μL),and start the timer, see illustration below.
    3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.
    10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection
    For IHI-401:
    Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
    1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it as soon as possible.

    2. For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25μL) to the specimen area, then add 1 drop of buffer (approximately 40 μL ),and start the timer, see ilustration below.
    For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50uL) to the specimen area, then add 2 drops of buffer (approximately 80μL), and start the timer. See ilustration below.
    For Fingerstick Whole Blood specimen:
    ●To use a capillary tube: Fill the capillary tube and transfer approximately 50μL of fingerstick whole blood specimen to the specimen area of test dipstick, then add 2 drops of buffer (approximately 80 μL) and start the timer. See ilustration below.
    ●To use hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 50μL) to fall into the specimen area of test dipstick, then add 2 drops of buffer (approximately 80 μL) and start the timer. See ilustration below.

    3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result
    For IHI-402:
    Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
    1. Remove the test Cassette from the sealed pouch and use it as soon as possible.
    2. Place the Cassette on a clean and level surface.
    For Serum or Plasma specimen: Hold the dropper vertically and transfer 1 drop of serum or plasma (approximately 25 μL) to the specimen area, then add 1 drop of buffer (approximately 40 μL),and start the timer, see illustration below.
    For Venipuncture Whole Blood specimen: Hold the dropper vertically and transfer 2 drops of whole blood (approximately 50 μL) to the specimen area, then add 2 drops of buffer (approximately 80μL), and start the timer. See illustration below.
    For Fingerstick Whole Blood specimen:
    To use a capillary tube: Fill the capillary tube and transfer approximately 50 μL of fingerstick whole blood specimen to the specimen area of test Cassette, then add 2 drops of buffer (approximately 80 μL) and start the timer. See illustration below.

    To use hanging drops: Allow 2 hanging drops of fingerstick whole blood specimen (approximately 50 μL) to fall into the specimen area of test Cassette, then add 2 drops of buffer (approximately 80 μL) and start the timer. See illustration below.
    3. Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.
    10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection
    INTERPRETATION OF RESULTS
    (Please refer to the illustration above)
    POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).
    *NOTE: The intensity of the color in the test line region (T) will vary depending on the concentration of HIV antibodies present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.
    NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).
    INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test cassette immediately and contact your local distributor.

    Order Information

    Cat. No.ProductSpecimenPack
    IHI-302HIV 1.2 Rapid Test CassetteS / P40 T
    IHI-401HIV 1.2 Rapid Test DipstickWB/S/P50T
    IHI-402HIV 1.2 Rapid Test CassetteWB/S/P40 T
    IHI-402SHIV 1.2 Rapid Test Cassette Single Use KitWB1 T
    IHI-T401HIV 1.2.O Rapid Test DipstickWB/S/P50T
    IHI-T402HIV 1.2.O Rapid Test CassetteWB/S/P40 T
    IHI-T402SHIV 1.2.O Rapid Test Cassette Single Use KitWB1 T
    IHIG-402HIV p24 Antigen Rapid test CassetteWB/S/P40 T
    IHIBG-425HIV 1.2 and HIV p24 Combo Rapid test CassetteWB/S/P25 T

    Quality 10 Minutes HIV 1.2 Rapid Test Dipstick Diagnosis Of HIV Infection for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: CITEST DIAGNOSTICS INC.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)