NND Rapid Test Cassette, Detection of N, N-Dimethyltryptamine in
urine,Drug Abuse Test Kit
Product: | NND Rapid Test Cassette, Detection Of N, N-Dimethyltryptamine In
Urine,Drug Abuse Test Kit |
Certificate: | CE |
Principle: | Chromatographic Immunoassay |
Reading Time: | 5 Minutes |
Storage Temperature: | 2-30°C |
Sensitivity: | 96.70% |
Accuracy: | 96.90% |
Cat. No.: | DNND-102 |
Format: | Dipstick, Cassette, Panel |
Specimen: | Urine |
Pack: | 40T |
Shelf Life: | 2 Years |
Specificity: | 97.00% |
Cut-Off: | 500 Ng/mL |
A rapid test for the qualitative detection of N,
N-Dimethyltryptamine in human urine.For professional in vitro
diagnostic use only.
INTENDED USE
The NND Rapid Test Cassette (Urine) is a rapid chromatographic
immunoassay for the detection of N, N-Dimethyltryptamine in urine
at a cut-off concentration of 1000 ng/mL. This test will detect
other related compounds, please refer to the Analytical Specificity
table in this package insert.
This assay provides only a qualitative, preliminary analytical test
result. A more specific alternate chemical method must be used in
order to obtain a confirmed analytical result.
Gas chromatography/mass spectrometry (GC/MS) is the preferred
confirmatory method. Clinical consideration and professional
judgment should be applied to any drug of abuse test result,
particularly when preliminary positive results are used.
SUMMARY
N, N-Dimethyltryptamine is a powerful and illegal hallucinogenic
drug. While there is an open debate on whether or not N,
N-Dimethyltryptamine is addictive, this drug poses dangerous
physical and psychological effects for frequent users.
Additionally, individuals who frequently abuse N,
N-Dimethyltryptamine often develop a dependence on the drug,
proving the dangers of N, N-Dimethyltryptamine abuse.
N, N-Dimethyltryptamine produces a high referred to as a
psychedelic trip. When smoked, a N, N-Dimethyltryptamine trip
usually begins instantly and lasts less than an hour.2 However,
when drunk in the form of Ayahuasca tea, hallucinations begin after
about 30 minutes and may last from 4-6 hours. Some users report
experiencing mild, lingering hallucinogenic effects for several
days after consuming or smoking
N, N-Dimethyltryptamine. On a physiological level, N,
N-Dimethyltryptamine causes an array of adverse side effects.The
NND Rapid Test Cassette (Urine) is a rapid urine-screening test
that can be performed without the use of an instrument. The test
utilizes the antibody to selectively detect elevated levels of N,
N-Dimethyltryptamine in urine. The NND Rapid Test Cassette(Urine)
yields a positive result when the N, N-Dimethyltryptamine in urine
exceed the cut-off level.
PRINCIPLE
The NND Rapid Test Cassette (Urine) is an immunoassay based on the
principle of competitive binding. Drugs which may be present in the
urine specimen compete against the drug conjugate for binding sites
on the antibody. During testing, a urine specimen migrates upward
by capillary action. N, N-Dimethyltryptamine, if present in the
urine specimen below the cut-off level, will not saturate the
binding sites of the antibody in the test. The antibody coated
particles will then be captured by immobilized N,
N-Dimethyltryptamine-protein conjugate and a visible colored line
will show up in the test line region. The colored line will not
form in the test line region if the N, N-Dimethyltryptamine level
exceeds the cut-off level, because it will saturate all the binding
sites of anti-N, N-Dimethyltryptamine antibody.
A drug-positive urine specimen will not generate a colored line in
the test line region because of drug competition, while a
drug-negative urine specimen or a specimen containing a drug
concentration less than the cut-off will generate a line in the
test line region. To serve as a procedural control, a colored line
will always appear at the control line region indicating that
proper volume of specimen has been added and membrane wicking has
occurred.
PRECAUTIONS
• For professional in vitro diagnostic use only.
• Do not use after the expiration date.
• The test should remain in the sealed pouch until use.
• All specimens should be considered potentially hazardous and
handled in the same manner as an infectious agent.
• The used test should be discarded according to local regulations.
DIRECTIONS FOR USE
Allow the test, urine specimen, and/or controls to reach room
temperature (15-30 °C) prior to testing.
1. the pouch to room temperature before opening it. Remove the test
cassette from the se Bring aled pouch and use it within one hour
2. Place the cassette on a clean and level surface. Hold the
dropper vertically and transfer
3 full drops of urine (approx. 120 µL) to the specimen well(S) of
the cassette, and then start the timer. Avoid trapping air bubbles
in the specimen well(S).
3. Wait for the colored line(s) to appear. Read results at 5
minutes. Do not interpret the result after 10 minutes.

INTERPRETATION OF RESULTS
(Please refer to the illustration above)
NEGATIVE: Two colored lines appear. One colored line should be in
the control line region (C), and another colored line should be in
the test line region (T). This negative result indicates that the
N, N-Dimethyltryptamine concentration is below the detectable
cut-off level.
NOTE: The shade of color in the test line region (T) may vary, but
it should be considered negative whenever there is even a faint
colored line.
POSITIVE: One colored line appears in the control line region (C).
No line appears in the test line region (T). This positive result
indicates that the N, N-Dimethyltryptamine concentration exceeds
the detectable cut-off level.
INVALID: Control line fails to appear. Insufficient specimen volume
or incorrect procedural techniques are the most likely reasons for
control line failure. Review the procedure and repeat the test with
a new test. If the problem persists, discontinue using the test kit
immediately and contact local distributor.
QUALITY CONTROL
A procedural control is included in the test. A colored line
appearing in the control line region (C) is considered an internal
procedural control. It confirms sufficient specimen volume,
adequate membrane wicking and correct procedural technique. Control
standards are not supplied with this kit; however, it is
recommended that positive and negative controls be tested as good
laboratory testing practice to confirm the test procedure and to
verify proper test performance.
Order Information
DNND-102 | NND Rapid Test Cassette | Urine | 40T | 500 ng/mL |
DNND-114 | NND Rapid Test Panel | Urine | 40T | 500 ng/mL |
DNND-101/111 | NND Rapid Test Dipstick | Urine | 50T | 500 ng/mL |