Sign In | Join Free | My himfr.com
Home > Fluorescence Immunoassay Test >

Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test

CITEST DIAGNOSTICS INC.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test from wholesalers
     
    Buy cheap Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test from wholesalers
    • Buy cheap Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test from wholesalers

    Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test

    Ask Lasest Price
    Brand Name : Citest
    Model Number : FI-CEA-302
    Certification : CE
    Price : negotiation
    Supply Ability : 10 M tests/month
    Delivery Time : 2-4 Weeks
    • Product Details
    • Company Profile

    Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test

    Convenient Carcinoembryonic Antigen (CEA) Test Easy Use By CItest GO fluorescence Immunoassay Analyzer Serum /Plasma


    Product featuresParameters
    PrincipleFluorescence Immunoassay
    FormatCassette
    SpecimenS/P
    CertificateCE
    Reading Time15 minutes
    Pack10T/25T
    Storage Temperature4-30℃
    Shelf Life2 Years
    Cut-Off4 ng/mL

    A test for measuring Carcinoembryonic Antigen (CEA) in serum or plasma with the use of CitestTM GO fluorescence Immunoassay


    Analyzer. For professional in vitro diagnostic use only.

    Features

    【PERFORMANCE CHARACTERISTICS】

    1. Accuracy

    The deviation is ≤ ±15%.

    2. Analytical sensitivity

    The CEA Test Cassette can detect levels of CEA as low as 1 ng/ml in serum, plasma.

    3. Linearity range

    1 – 500 ng/ml , R≥0.990

    4. Precision

    C.V. ≤15%


    Fast Result (15 minutes)

    Simple Operation (Less Training Required)

    Objective (Results Read by Analyzer)

    Stringent Quality Control Insure High Accuracy

    User-friendly (Simple Plug & Play Operation)

    High Efficiency (Both STAT Testing and Batch Testing)


    Application:


    The CEA Test Cassette (Serum/Plasma) is based on Fluorescence immunoassay for the quantitative detection of CEA in serum or plasma to aid in monitoring of cancer patients.


    Description:


    Carcinoembryonic Antigen (CEA) is a tumor-associated antigen characterized as an oncofetal glycoprotein. CEA is expressed in a variety of malignancies, particularly pulmonary or gastrointestinal tumors (e.g. colon cancer, liver cancer and lung cancer). CEA normally occurs in fetal gut tissue with detectable serum levels essentially disappearing after birth. Therefore, elevated levels of CEA can be of significant value in the diagnosis of primary carcinomas. In addition to quantitative assessment, CEA testing plays an important role in the monitoring of cancer patients.


    Clinical evidence indicates that CEA levels can serve as predictive markers in both pre- and post-treatment of cancer. Progressive elevation of CEA may signal tumor recurrence 3-36 months before clinical evidence of metastasis. Persistent elevation of circulating CEA following treatment is strongly indicative of occult metastatic and residual diseases and deficient therapeutic response.


    How to use?


    Refer to CitestTM GO Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be in room temperature.


    Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.


    1. Turn on the Analyzer power. Then according to the need, select “standard test” or “Quick test” mode.


    2. Remove the ID card and insert it into the Analyzer ID Card Slot.


    3. Pipette 50 μLof serum or plasma into the buffer tube, mix the specimen and the buffer well.


    4. Pipette 75 μL diluted sample into the sample well of the cassette. Start the timer at the same time.


    5. There are two test modes for CitestTM GO Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode.


    Please refer to the user manual of CitestTM GO Fluorescence Immunoassay Analyzer for details.


    “Quick test” mode: After 15 minutes of adding sample,Insert the test cassette into the Analyzer click “QUICK TEST”, fill the test information and click "NEW TEST" immediately. The Analyzer will automatically give the test result after a few seconds.

    “Standard test” mode: Insert the test cassette into the Analyzer immediately after adding specimen, click “STANDARD TEST”, fill the test information and click "NEW TEST" at the same time. The Analyzer will automatically countdown 15 minutes. After the countdown, the Analyzer will give the result at once.


    Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test


    INTERPRETATION OF RESULTS


    Results read by CitestTM GO Fluorescence Immunoassay Analyzer.
    The result of tests for CEA is calculated by Citest TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of CitestTM GO.
    Fluorescence Immunoassay Analyzer.
    Linearity range of Citest TM CEA is 1-500 ng/mL.
    Reference range:<4ng/ml.


    Catalogue NumberItem NameSampleTest RangeKIT size
    FI-CEA-302CEA Test CassetteS/P1~500 ng/mL10T/25T
    Quality Citest CEA Fluorescence Immunoassay Test Carcinoembryonic Antigen Test for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: CITEST DIAGNOSTICS INC.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)